Please use this identifier to cite or link to this item:
http://148.72.244.84/xmlui/handle/xmlui/13810
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Baidaa Nihad | - |
dc.contributor.author | Khattab S. Abdul-Razzaq | - |
dc.contributor.author | Adham Abdulsattar Hameed | - |
dc.date.accessioned | 2024-04-03T15:09:27Z | - |
dc.date.available | 2024-04-03T15:09:27Z | - |
dc.date.issued | 2022-12-01 | - |
dc.identifier.citation | https://djes.info/index.php/djes/article/view/1018 | en_US |
dc.identifier.issn | 1999-8716 | - |
dc.identifier.uri | http://148.72.244.84:8080/xmlui/handle/xmlui/13810 | - |
dc.description.abstract | This parametric study used finite element method (ETABS 2019), on 20 elliptical reinforced concrete cantilever deep beam specimens that have rectangular sections. Five parameters were taken into consideration: beam height, beam width, concrete compressive strength, load position and load type. Results showed that when the beam height was increased by 12%–66.5%, the negative and torsional moments and load capacity increased by about 11.23%–76.33%, 11.2%–77% and 11.1%–78%, respectively, whereas deflection decreased by about 15%–39%. The negative and torsional moments and load capacity increased by 26.13%–166.53%, 27%–172.5% and 28%–180%, respectively, and a decrease in deflection of about 1.73%–2.3% took place when beam width increased by about 14.3%–81%. In addition, increasing the compressive strength of concrete by 7.5%–36% led to an increase in the negative moments, torsional moments, load capacity, and deflection by about 8.22%–19.2%, 8.7%–20.4%, 9.4%–22% and 4.7%–7.1%, respectively. When changing the load type from concentrated to uniformly distributed over a third of the span’s length, two-thirds of the span’s length and then over the full span’s length, the negative moments increased by 5.23%, 8.47% and 52.67%, whereas torsional moments decreased by 1.1%, 1.12% and 16%, respectively. Finally, placing the concentrated load at a distance of 0.75, 0.5 and 0.25 of the span lengths led the negative moments to increase by 56.9%, 102.3% and 110%, respectively, whereas torsional moments decreased by 8.64%, 25%, and 58.3%, respectively. The load capacity increased by 87.5%, 243.75% and 556.25%, respectively, accompanied by a decrease in the deflection of the free end by 3.24%, 17.65% and 49.8%, respectively. | en_US |
dc.language.iso | en | en_US |
dc.publisher | University of Diyala – College of Engineering | en_US |
dc.subject | Parametric Study, Reinforced Concrete, Cantilever, Deep Beams, Finite Element | en_US |
dc.title | A Parametric Study on Behavior of Elliptical Cantilever Deep Beams | en_US |
dc.type | Article | en_US |
Appears in Collections: | مجلة ديالى للعلوم الهندسية / Diyala Journal of Engineering Sciences (DJES) |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
3-1018.pdf | 1.12 MB | Adobe PDF | View/Open |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.